Description
Specifications
Surge immunity*
Surge Immunity (EN-IEC 61000-4-5:2014): Level 4
Maximum line-to-line surge**: 2 kV, 1 kA
Maximum line-to-ground surge**: 4 kV, 2 KA
Number of protected instruments: up to 3
Data lines
Common mode signal voltage range: ± 12 V
Differential mode signal voltage range: ± 12 V
Maximum line-to-earth voltage: 12 V
Mechanical
Housing material: ASA/PC UL94 V0-1.5mm
Cable glands: M12 (protected)
Cable diameter: (3 to 6) mm
Optional SMF01: rated pole mount diameter: (40 to 60) mm
Weight: 0.7 kg
DC power lines
Rated operating DC input voltage range: ± 30 V
Maximum DC input current: 5 A
Total DC output current: 5 A
Rated operating conditions
Required over-current protection: ≤ 5 A slow blow fuse
Rated operating temperature range: (-40 to +80) °C
* tested with all HUkseflux Industrial pyranometers